Edit in Desk ↗Strongback lock sensor false positive — catch attempt aborted
Awaiting Customerteam@spacex.demo · 2026-10-09 11:31:51 · ISS-SPAX-0006
Customer
No customer linked
Machine / asset
No machine linked
DisciplineAutomation
PriorityHigh
Spares statusShipped
Last updated2026-10-16 03:31
Description
Sensor B7 on the strongback locking mechanism reports a locked state while the mechanism is in transit. Aborted the IFT-6 catch on the first attempt.
Work log
Currently: Waiting3 entries- ACavery.chenWaitingOct 16 · 03:31 AM
Blocked on tower access — next window is after the static fire campaign.
- ACavery.chenShippedOct 14 · 01:31 AM
Shielded replacement sensor shipped to the tower crew.
- ACavery.chenDiagnosedOct 9 · 09:31 PM
Inductive sensor is picking up the adjacent actuator body at the midpoint of travel.
Spares required
1