Description
Sensor B7 on the strongback locking mechanism reports a locked state while the mechanism is in transit. Aborted the IFT-6 catch on the first attempt.
Work log
Currently: Waiting3 entries- ACavery.chenWaitingAug 13 · 11:16 PM
Blocked on tower access — next window is after the static fire campaign.
- ACavery.chenShippedAug 11 · 09:16 PM
Shielded replacement sensor shipped to the tower crew.
- ACavery.chenDiagnosedAug 7 · 05:16 PM
Inductive sensor is picking up the adjacent actuator body at the midpoint of travel.