← US Space Force
Edit in Desk ↗Grid fin actuator response lag >40ms under thermal soak
Investigatingteam@spacex.demo · 2026-08-12 21:16:33 · ISS-SPAX-0003
Customer
US Space Force
Americas · owner: casey.kim
Machine / asset
Merlin 1DMerlin 1D
serial M1D-RG-0207 · MACH-0003
DisciplineElectrical
PriorityMedium
Spares statusIdentified
Last updated2026-08-15 06:16
Description
Actuator response exceeds the 40ms spec under sustained 80°C thermal soak during the re-entry profile simulation. Repeatable across three runs.
Work log
Currently: In progress2 entries- CKcasey.kimIn progressAug 14 · 03:16 PM
Swapped in a spare amplifier from stores; re-running the soak profile overnight.
- CKcasey.kimDiagnosedAug 13 · 03:16 AM
Lag tracks with driver board temperature, not with hydraulic pressure. Points at the servo amplifier, not the actuator.
Spares required
1
Actions
Move to
Classification