Demo mode · SpaceX fixture data · no live backend
2
SES S.A.

TPS bond oven zone 3 will not hold setpoint

Awaiting Spares

team@spacex.demo · 2026-08-13 11:16:33 · ISS-SPAX-0015

Edit in Desk ↗
Customer
SES S.A.
Europe · owner: quinn.nakamura
Machine / asset
Starship TPSStarship TPS
serial TPS-OV-0088 · MACH-0005
DisciplineElectrical
PriorityHigh
Spares statusOrdered
Last updated2026-08-14 23:16

Description

Zone 3 heating element drifts 14°C below setpoint after roughly 40 minutes at temperature, which puts the cure profile out of tolerance. Oven is out of service.

Work log

Currently: Waiting2 entries
  1. QNquinn.nakamuraWaitingAug 14 · 11:16 PM

    Element on order via Hexcel. Customer informed the oven is down for roughly a week.

  2. QNquinn.nakamuraDiagnosedAug 13 · 01:16 PM

    Element resistance is out of band. Thermocouple checks good, so it is the element rather than the loop.

Spares required

1

Timeline

operations@ses.demo2026-08-15 00:16

Understood on the week outage. We have moved the next cure batch to the Kennedy press — please confirm that does not affect the qualification paperwork.

Actions

Move to

Classification