← NASA
Edit in Desk ↗Dragon ECLSS CO₂ scrubber throughput 12% below spec
Investigatingteam@spacex.demo · 2026-08-14 19:16:33 · ISS-SPAX-0008
Customer
NASA
Americas · owner: alex.reeves
Machine / asset
Starship TPSStarship TPS
serial TPS-PR-0042 · MACH-0002
DisciplineMechanical
PriorityHigh
Spares statusNone
Last updated2026-08-15 11:16
Description
CO₂ removal rate measured at 88% of rated capacity in acceptance testing. Crew-11 hold pending resolution.
Work log
Currently: Diagnosed2 entries- ROriley.okonkwoDiagnosedAug 15 · 11:16 AM
Sorbent bed packing density is at the low end of the allowed band. Chasing the vendor lot data.
- ROriley.okonkwoReviewedAug 14 · 09:16 PM
Reproduced on the flight article and on the spare. Not a one-off unit defect.
Actions
Move to
Classification