← European Space Agency
Edit in Desk ↗Igniter cell interlock nuisance-trips on cold start
Closedteam@spacex.demo · 2026-07-25 · ISS-SPAX-0016
Customer
European Space Agency
Europe · owner: casey.kim
Machine / asset
Merlin 1DMerlin 1D
serial M1D-IG-0459 · MACH-0006
DisciplineAutomation
PriorityMedium
Spares statusNone
Last updated2026-08-07 07:16
Description
Igniter cell safety interlock trips on the first start of the day when ambient is below roughly 10°C, requiring a manual reset before the campaign can begin.
Work log
Currently: Shipped3 entries- CKcasey.kimShippedAug 7 · 07:16 AM
PLC recipe updated on site and signed off by the ESA test lead.
- CKcasey.kimFixedAug 2 · 07:16 AM
Threshold re-characterised across the full ambient range.
- CKcasey.kimReviewedJul 25 · 07:16 PM
Reproduced on a cold morning at Kourou. Only ever the first start.
Resolution
Interlock threshold was calibrated at 20°C ambient. Re-characterised across the full 5–35°C range and the trip point moved into the PLC recipe so it is site-adjustable.
Actions
Move to
Classification